Dismantling & Telescopic Joints
VSSJAFG (CF) Single Flange Dismantling Joint
The VSSJAFG (CF) is a single flange dismantling joint with loose-sleeve installation adjustment and a restrained force-transmission configuration.
Also specified as a VSSJAFG CF single flange force transmission joint or single flange power transmission joint.
- Model
- VSSJAFG (CF)
- Product Type
- Single Flange Dismantling Joint
- Size Range
- DN65–DN3200
- Connection
- Single flange + project-specific opposite pipe / interface
- Function
- Installation adjustment and force-transmission configuration
- Standard
- Factory confirmation required
CustomizationDimensions, interfaces, materials and coating can be reviewed against project data and the approved drawing.
Project Configuration
Mingchao can customize the product configuration based on the technical information, operating conditions and dimensional data you provide. Final configuration can be reviewed and manufactured to the approved project drawing.
VSSJAFG (CF) Single Flange Dismantling Joint Overview
The Mingchao VSSJAFG (CF) is a single-flange loose-sleeve force-transmission joint for pipeline installations requiring a flanged connection on one side and a project-specific pipe connection on the opposite side. The adjustable assembly supports installation and maintenance positioning, while the restrained fastener arrangement forms the required force-transmission configuration after final alignment.
Final selection depends on pipe outside diameter, face-to-face length, connection geometry, flange drilling, operating conditions and the approved project drawing.
How the CF Configuration Works
The CF assembly uses a flanged connection on one side and a project-specific pipe or interface arrangement on the opposite side. Its loose-sleeve geometry supports positioning during installation. After alignment, the restrained fastener arrangement establishes the required force-transmission configuration.
Final pipe outside diameter, connection geometry, flange drilling and installation envelope are controlled by the approved project drawing.
Materials & Construction
Material selection must be reviewed against the medium, operating conditions and approved project drawing.
| Component | Material |
|---|---|
| Valve body | QT450-10 / Q235A |
| Gasket | NBR / EPDM / CR |
| Follower | QT450-10 / Q235A |
| Limited short pipe | Q235A |
| Bolt | Q235A / 35# |
| Nut | Q235A / 20# |
Main Connection Dimensions
The table lists 28 CF configurations from DN65 to DN3200. Dimensions are in millimetres unless stated otherwise. The 0.6 MPa and 1.0 MPa groups identify catalog connection-dimension groups, not a published working-pressure claim.
| DN | Pipe OD Dw (mm) | D0 (mm) | L (mm) | ΔL (mm) | 0.6 MPa D (mm) | 0.6 MPa D1 (mm) | 0.6 MPa n-Th. | 0.6 MPa b (mm) | 1.0 MPa D (mm) | 1.0 MPa D1 (mm) | 1.0 MPa n-Th. | 1.0 MPa b (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 65 | 76 | 76 | 400 | 40 | 160 | 130 | 4-M12 | 16 | 185 | 145 | 4-M16 | 20 |
| 80 | 89 | 89 | 400 | 40 | 190 | 150 | 4-M16 | 18 | 200 | 160 | 8-M16 | 22 |
| 100 | 114 | 114 | 400 | 40 | 210 | 170 | 4-M16 | 18 | 220 | 180 | 8-M16 | 24 |
| 125 | 140 | 140 | 400 | 40 | 240 | 200 | 8-M16 | 20 | 250 | 210 | 8-M16 | 26 |
| 150 | 168 | 168 | 400 | 40 | 265 | 225 | 8-M16 | 20 | 285 | 240 | 8-M20 | 26 |
| 200 | 219 | 219 | 400 | 40 | 320 | 280 | 8-M16 | 22 | 340 | 295 | 8-M20 | 28 |
| 250 | 273 | 273 | 400 | 40 | 375 | 335 | 12-M16 | 24 | 395 | 350 | 12-M20 | 28 |
| 300 | 325 | 325 | 420 | 50 | 440 | 395 | 12-M20 | 24 | 445 | 400 | 12-M20 | 28 |
| 350 | 377 | 377 | 420 | 50 | 490 | 445 | 12-M20 | 26 | 505 | 460 | 16-M20 | 30 |
| 400 | 426 | 426 | 420 | 50 | 540 | 495 | 16-M20 | 28 | 565 | 515 | 16-M24 | 32 |
| 450 | 480 | 480 | 420 | 50 | 595 | 550 | 16-M20 | 28 | 615 | 565 | 20-M24 | 32 |
| 500 | 530 | 530 | 420 | 50 | 645 | 600 | 20-M20 | 30 | 670 | 620 | 20-M24 | 34 |
| 600 | 630 | 630 | 440 | 50 | 755 | 705 | 20-M24 | 30 | 780 | 725 | 20-M27 | 36 |
| 700 | 720 | 720 | 440 | 50 | 860 | 810 | 24-M24 | 32 | 895 | 840 | 24-M27 | 40 |
| 800 | 820 | 820 | 600 | 60 | 975 | 920 | 24-M27 | 34 | 1015 | 950 | 24-M30 | 44 |
| 900 | 920 | 920 | 600 | 60 | 1075 | 1020 | 24-M27 | 36 | 1115 | 1050 | 28-M30 | 46 |
| 1000 | 1020 | 1020 | 600 | 60 | 1175 | 1120 | 28-M27 | 36 | 1230 | 1160 | 28-M33 | 50 |
| 1200 | 1220 | 1220 | 620 | 60 | 1405 | 1340 | 32-M30 | 40 | 1455 | 1380 | 32-M36 | 56 |
| 1400 | 1420 | 1428 | 620 | 60 | 1630 | 1560 | 36-M33 | 44 | 1675 | 1590 | 36-M39 | 62 |
| 1600 | 1620 | 1628 | 630 | 60 | 1830 | 1760 | 40-M33 | 48 | 1915 | 1820 | 40-M45 | 68 |
| 1800 | 1820 | 1828 | 630 | 60 | 2045 | 1970 | 44-M36 | 50 | 2115 | 2020 | 44-M45 | 70 |
| 2000 | 2020 | 2030 | 650 | 60 | 2265 | 2180 | 48-M39 | 54 | 2325 | 2230 | 48-M45 | 74 |
| 2200 | 2220 | 2230 | 650 | 60 | 2475 | 2390 | 52-M39 | 60 | 2550 | 2440 | 52-M52 | 80 |
| 2400 | 2420 | 2430 | 650 | 60 | 2685 | 2600 | 56-M39 | 62 | 2760 | 2650 | 56-M52 | 82 |
| 2600 | 2620 | 2630 | 750 | 80 | 2905 | 2810 | 60-M45 | 64 | 2960 | 2850 | 60-M52 | 88 |
| 2800 | 2820 | 2830 | 750 | 80 | 3115 | 3020 | 64-M45 | 68 | 3180 | 3070 | 64-M52 | 94 |
| 3000 | 3020 | 3030 | 750 | 80 | 3315 | 3220 | 68-M45 | 70 | 3405 | 3290 | 68-M56 | 100 |
| 3200 | 3220 | 3230 | 750 | 80 | 3525 | 3430 | 72-M45 | 76 |
Blank cells remain blank where the catalog lists no value. Confirm interface dimensions, drilling and operating conditions before ordering.
BF vs. CF vs. C2F Selection Guidance
| Product Type | Configuration |
|---|---|
| VSSJA-1 (BF) | Single flange; limited telescopic configuration for installation adjustment. |
| VSSJAFG (CF) | Single flange; loose-sleeve adjustment plus force-transmission configuration. |
| VSSJAF (C2F) | Double flange; standard double-flange force-transmission and dismantling configuration. |
Applications
Water Transmission
Pipeline interfaces requiring CF connection geometry.
Water Treatment
Project-specific equipment and pipeline connections.
Pumping Stations
Pump or valve interfaces subject to approved project conditions.
Utility Pipelines
Installation and maintenance interfaces in infrastructure piping.
Industrial Piping
Custom connection geometry after operating conditions are reviewed.
Suitability depends on the confirmed medium, pressure and temperature requirements, external loads, installation geometry and material compatibility.
Custom Project Options
Mingchao can review DN or NPS, pipe OD, face-to-face length, installation and connection geometry, flange dimensions, drilling and PCD, bolt pattern, materials, gasket, fasteners and coating against the customer CAD, PDF or drawing.
Final manufacture is subject to the approved project drawing.
Engineering / RFQ Data
- Working pressure, test pressure and temperature: Factory confirmation required.
- Flange standard, testing and certificates: Factory confirmation required.
- Installation envelope and project loads: Engineering calculation on request.
- Provide model, DN, pipe OD, face-to-face, opposite-side interface, flange drilling, medium, materials, coating, drawing, quantity and project location.
Product Images, Structural Drawing & Connection Dimensions



Information Required for Selection & Quotation
Provide available project information for CF configuration review.
- Model / configuration
- DN and pipe outside diameter
- Face-to-face length
- Flange standard and drilling
- Opposite-side pipe / interface
- Pressure requirement and medium
- Materials and coating
- Installation geometry and drawing
Quantity and project location