Dismantling & Telescopic Joints
VSSJAFC (CC2F) Detachable Double Flange Dismantling Joint
The VSSJAFC (CC2F) is a detachable double flange dismantling joint with an extended removable assembly for project-specific valve, pump and pipeline connections.
Also specified as a VSSJAFC CC2F detachable double flange force transmission joint or removable double flange dismantling joint.
- Model
- VSSJAFC (CC2F)
- Product Type
- Detachable Double Flange Dismantling Joint
- Size Range
- DN65–DN3200
- Connection
- Detachable extended double-flange assembly
- Function
- Installation adjustment, force transmission and detachable connection
- Standard
- Factory confirmation required
CustomizationDetachable geometry, dimensions, interfaces, materials and coating can be reviewed against the approved drawing.
Project Configuration
Mingchao can customize the product configuration based on the technical information, operating conditions and dimensional data you provide. Final configuration can be reviewed and manufactured to the approved project drawing.
VSSJAFC (CC2F) Detachable Double Flange Dismantling Joint Overview
The Mingchao VSSJAFC (CC2F) is a detachable double-flange loose-sleeve force-transmission joint. Its extended removable assembly distinguishes it from the standard compact C2F configuration and supports project layouts that require a detachable pipeline or equipment interface.
Final selection depends on DN, face-to-face length, flange drilling, detachable geometry, maintenance clearance, installation envelope, operating conditions and the approved project drawing.
What Makes the CC2F Configuration Detachable
The CC2F uses an extended double-flange assembly with a distinct removable connection section. This architecture provides a detachable interface for project layouts where installation envelope and maintenance clearance must be considered.
The sleeve, follower, gasket and stud arrangement must be selected as one CC2F configuration. Final detachable geometry and clearance are controlled by the approved project drawing.
CC2F vs. C2F Selection Guidance
| Product Type | Configuration |
|---|---|
| VSSJAF (C2F) | Standard compact double-flange force-transmission and dismantling architecture. |
| VSSJAFC (CC2F) | Detachable extended double-flange architecture with a distinct removable assembly and longer face-to-face series. |
Materials & Construction
Material selection must be reviewed against the medium, operating conditions and approved project drawing.
| Component | Material |
|---|---|
| Valve body | QT450-10 / Q235A |
| Gasket | NBR / EPDM / CR |
| Follower | QT450-10 / Q235A |
| Limited short pipe | Q235A |
| Stud | Q235A / 35# |
| Nut | Q235A / 20# |
Main Connection Dimensions
The table lists 28 CC2F configurations from DN65 to DN3200. Dimensions are in millimetres unless stated otherwise. The 0.6 MPa and 1.0 MPa groups are catalog connection-dimension groups, not a published working-pressure claim.
| DN | Pipe OD Dw (mm) | L (mm) | ΔL (mm) | 0.6 MPa D (mm) | 0.6 MPa D1 (mm) | 0.6 MPa n-Th. | 0.6 MPa b (mm) | 1.0 MPa D (mm) | 1.0 MPa D1 (mm) | 1.0 MPa n-Th. | 1.0 MPa b (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 65 | 76 | 400 | 40 | 160 | 130 | 4-M12 | 16 | 185 | 145 | 4-M16 | 20 |
| 80 | 89 | 400 | 40 | 190 | 150 | 4-M16 | 18 | 200 | 160 | 8-M16 | 22 |
| 100 | 114 | 400 | 40 | 210 | 170 | 4-M16 | 18 | 220 | 180 | 8-M16 | 24 |
| 125 | 140 | 400 | 40 | 240 | 200 | 8-M16 | 20 | 250 | 210 | 8-M16 | 26 |
| 150 | 168 | 400 | 40 | 265 | 225 | 8-M16 | 20 | 285 | 240 | 8-M20 | 26 |
| 200 | 219 | 400 | 40 | 320 | 280 | 8-M16 | 22 | 340 | 295 | 8-M20 | 28 |
| 250 | 273 | 400 | 40 | 375 | 335 | 12-M16 | 24 | 395 | 350 | 12-M20 | 28 |
| 300 | 325 | 420 | 50 | 440 | 395 | 12-M20 | 24 | 445 | 400 | 12-M20 | 28 |
| 350 | 377 | 420 | 50 | 490 | 445 | 12-M20 | 26 | 505 | 460 | 16-M20 | 30 |
| 400 | 426 | 420 | 50 | 540 | 495 | 16-M20 | 28 | 565 | 515 | 16-M24 | 32 |
| 450 | 480 | 420 | 50 | 595 | 550 | 16-M20 | 28 | 615 | 565 | 20-M24 | 32 |
| 500 | 530 | 420 | 50 | 645 | 600 | 20-M20 | 30 | 670 | 620 | 20-M24 | 34 |
| 600 | 630 | 440 | 50 | 755 | 705 | 20-M24 | 30 | 780 | 725 | 20-M27 | 36 |
| 700 | 720 | 440 | 50 | 860 | 810 | 24-M24 | 32 | 895 | 840 | 24-M27 | 40 |
| 800 | 820 | 600 | 60 | 975 | 920 | 24-M27 | 34 | 1015 | 950 | 24-M30 | 44 |
| 900 | 920 | 600 | 60 | 1075 | 1020 | 24-M27 | 36 | 1115 | 1050 | 28-M30 | 46 |
| 1000 | 1020 | 600 | 60 | 1175 | 1120 | 28-M27 | 36 | 1230 | 1160 | 28-M33 | 50 |
| 1200 | 1220 | 650 | 60 | 1405 | 1340 | 32-M30 | 40 | 1455 | 1380 | 32-M36 | 56 |
| 1400 | 1420 | 650 | 60 | 1630 | 1560 | 36-M33 | 44 | 1675 | 1590 | 36-M39 | 62 |
| 1600 | 1620 | 670 | 60 | 1830 | 1760 | 40-M33 | 48 | 1915 | 1820 | 40-M45 | 68 |
| 1800 | 1820 | 670 | 60 | 2045 | 1970 | 44-M36 | 50 | 2115 | 2020 | 44-M45 | 70 |
| 2000 | 2020 | 700 | 60 | 2265 | 2180 | 48-M39 | 54 | 2325 | 2230 | 48-M45 | 74 |
| 2200 | 2220 | 730 | 60 | 2475 | 2390 | 52-M39 | 60 | 2550 | 2440 | 52-M52 | 80 |
| 2400 | 2420 | 730 | 60 | 2685 | 2600 | 56-M39 | 62 | 2760 | 2650 | 56-M52 | 82 |
| 2600 | 2620 | 840 | 80 | 2905 | 2810 | 60-M45 | 64 | 2960 | 2850 | 60-M52 | 88 |
| 2800 | 2820 | 840 | 80 | 3115 | 3020 | 64-M45 | 68 | 3180 | 3070 | 64-M52 | 94 |
| 3000 | 3020 | 840 | 80 | 3315 | 3220 | 68-M45 | 70 | 3405 | 3290 | 68-M56 | 100 |
| 3200 | 3220 | 840 | 80 | 3525 | 3430 | 72-M45 | 76 |
Blank cells remain blank where the catalog lists no value. Confirm face-to-face, flange dimensions, drilling, detachable geometry and operating conditions before ordering.
Applications & Maintenance Access
Valve Connections
Detachable interfaces subject to approved project geometry.
Pump Connections
Equipment connections where removal access must be planned.
Water Transmission
Project-specific double-flange pipeline connections.
Water Treatment & Pumping Stations
Valve, pump and equipment interfaces.
Utility & Industrial Piping
Installations requiring detachable connection and defined clearance.
Suitability and maintenance access depend on operating conditions, installation envelope, external loads, materials and the approved drawing.
Custom Project Options
Mingchao can review DN, pipe interface, face-to-face length, detachable assembly geometry, maintenance clearance, installation envelope, flange standard and drilling, PCD, bolt pattern, materials, gasket, studs and coating against customer CAD, PDF or drawing.
Final manufacture is subject to the approved project drawing.
Engineering / RFQ Data
- Working pressure, test pressure and temperature: Factory confirmation required.
- Testing and certificates: Factory confirmation required.
- Maintenance clearance and installation envelope: Project-specific.
- Provide model, DN, interface, face-to-face, flange drilling, operating requirements, materials, detachable requirement, drawing, quantity and project location.
Product Images, Structural Drawing & Connection Dimensions



Information Required for Selection & Quotation
Provide available project information for CC2F review.
- Model / configuration and detachable requirement
- DN and pipe interface
- Face-to-face length
- Flange standard and drilling
- Pressure requirement and medium
- Materials and coating
- Maintenance clearance and installation envelope
- Project drawing
Quantity and project location